Wearable Inertial Sensors for Centre of Mass Stability Changes Report

Exclusively available on Available only on IvyPanda®
Updated:
This academic paper example has been carefully picked, checked and refined by our editorial team.
You are free to use it for the following purposes:
  • To find inspiration for your paper and overcome writer’s block
  • As a source of information (ensure proper referencing)
  • As a template for you assignment

Introduction

Historic and Current State of Knowledge in the Field of Your Project

The capacity to control the body’s position in space with the end goal of development and equilibrium is known as postural stability (Howell et al., 2017). It is essential for keeping a static position and helping body coordination in powerful position changes. There have been few wearable advances to assess body movement in light of micro-electro-mechanical sensors (MEMS) (Lau & Shrestha., 2017). The key benefits of body-wearable sensors are their minimal expense and convenient use in numerous conditions. Body-wearable sensors regularly comprise one or a mix of accelerometers, precise speed sensors, and magnetometers, giving important information in research. By appending these sensors to a body section, they permit estimation of fragment movement or body influence while performing balance undertakings. Wearable advances are likewise sufficiently delicate to follow changes in post-meditation postural control.

Study Problem

Critical difficulties in utilizing wearable sensors incorporated their failure to extricate helpful clinical information. Therefore, an improved biomechanical human body model with the base number of sensor connections required should be carried out with such innovation to make them appropriate for clinical applications (Ghislieri et al., 2019). Then again, model rearrangements might modify framework exactness. Consequently, there was an ideal trade-off between precision and the least number of sensor connections given.

Study Project Aims and its Contribution to Fill Gaps in Current Knowledge

The aim of this study is to investigate the precision of wearable sensors to assess the center of mass (COM) direction during huge body fragment developments (Carpentier, Benallegue and Laumond, 2017). In this research, we used the incremental shuttle walk test (ISWT) to investigate the exactness of the principle contributions of the proposed model. Two tests helped to analyze the various contributions of the last model. There were a total of 8 recruited participants. During the ISWT, the strolling distance was normalized to 10 meters for each lap, while the strolling speed had bit by bit increments from 0.50 m/s at level 1 to 2.37 m/s at level 12 (Houchen-Wolloff et al., 2018). As time diminished, the strolling speed increased with each level along these lines. This finding might open new roads for surveying and working on postural control in patients and competitors by planning novel standards that were unachieved in the past because of the limit of past advancements.

Project Scope and Possible Limitations

The study used two inertial sensors, a triaxial accelerometer and a gyroscope. The sensors gave continuous kinematic information, including speed increase and speed of revolution. These points would depict a grouping of three pivots deciding the direction of a rigid body in three aspects in their request for application. The utilization of the following three-layered points to gauge the direction of a member’s sections, for example, upper back, contingent upon the worked on human body model. We expected each body section to be inflexible (Hsu et al., 2018). Hence, we assumed that the wearable sensors gave fragment points straightforwardly (Ravindra et al., 2018). The reflective marker positioned on the lumbar spine’s lowest vertebrae, L4, and then two wearable sensors would be attached to the participant with the reflective marker.

In this research, we used the incremental shuttle walk test (ISWT) to investigate the exactness of the principle contributions of the proposed model. Two tests helped to analyze the various contributions of the last model. There was a total of 8 recruited participants. During the ISWT, the strolling distance was normalized to 10 meters for each lap, while the strolling speed had bit by bit increments from 0.50 m/s at level 1 to 2.37 m/s at level 12 (Houchen-Wolloff et al., 2018). As time diminished, the strolling speed increased with each level along these lines. The finding might open new roads for surveying and working on postural control in patients and competitors by planning novel standards that were unachieved in the past because of the limit of past advancements.

At first, the subjects would remain in an impartial, upstanding state to sync the markers’ place and the zero spot’s sensors, and then, after a step, return to the original position. The pinnacle of this development was to synchronize the two frameworks before each progression. After two steps, right and left, were performed, the information gathered was recreated involving MATLAB programming for correlation between the sensors (Kumar et al., 2019). The result of the information utilizing the MATLAB model was then set as the reference standard to assess the precision of the sensor information model.

Discussion

To assess the COM position, we would expect that the body would be standing and displayed by a one-connection model. The proximal segment was in two sections (shank and thigh) which accounted for the bending of the knees ([[theta].sub.k]). Therefore, the CoM equation based on a three-link model can be as follows: COM = [K.sub.1] x sin [[theta].sub.a] + [K.sub.2] x sin [[theta].sub.h] + [K.sub.3] x sin [[theta].sub.k] (Wilkinson and Lichtwark, 2021)

Where:

[K.sub.1] = [[m.sub.1] x [T.sub.1] + [m.sub.2] x [L.sub.1] + [m.sub.3] x [L.sub.1]]/[[m.sub.1] + [m.sub.2] + [m.sub.3]]; [K.sub.2] = [[m.sub.2] x [T.sub.2] + [m.sub.3] x [L.sub.2]]/[[m.sub.1] + [m.sub.2] + [m.sub.3]]; [K.sub.3] = [[m.sub.3] x [T.sub.3]]/[[m.sub.1] + [m.sub.2] + [m.sub.3]]

Orderly and irregular mistakes were assessed, individually, by ascertaining mean and standard deviation of blunders. The MATLAB clock (Tic-Toc function) helped in the investigation of the proposed model and calculations permit continuous assessment of body section point and COM direction; we controlled the execution of every preliminary for assessing and recording 3D points of two portions working out COM direction (Nachamai, Paulose and Marandi, 2018). We expected the execution of the calculation assuming the time expected for assessment of each time test is under 0.0167sec relating to test recurrence of 60Hz utilized in our review. All calculations and statistical analysis used MATLAB (Noacco et al., 2019). This review proposes a creative, compact, and savvy wearable sensor innovation gauge COM direction while standing, performing straightforward errands and doing athletic developments (Huntley et al., 2017). The proposed framework permits progressively assessing 3D body portion points with somewhat low blunders in the A-P and M-L headings.

The irregular slip of around 2 degrees contrasts well and other announced values utilizing MEMS innovation on the knee or arm movements where there was accountability of accuracy of under 4[degrees] (Wan et al., 2018). Part of our assessment mistakes could happen because the A-P bearing of the member was outwardly adjusted to the Y-pivot to look at the developments every way, which may expand the mistake of assessment.

Moreover, inconsistencies can also represent the exploratory convention, the marker arrangement, and skin development. Regardless of these restrictions, the assessed exactness was somewhat high and had all the earmarks of being enough for assessment of COM direction. This study also explored the accuracy of different simplified models for estimating the trajectory of COM. We established that means of estimation of lower back movement do not exactly represent COM motion, especially during fast movements.

In addition, there was the consideration of shank and lower back movements less influenced by skin movement because of less body fat in these segments. One of the vital benefits of the proposed approach is its capacity for continuous execution. Utilizing the Matlab clock (Tic-Toc work), we controlled the execution of every preliminary for assessing and recording 3D points of two portions, ascertaining CoM direction, and showing the outcomes all inside the span of 0.0167 [+ or – ] 0.0008 seconds which is comparable to 60Hz testing rate. Continuous assessment of CoM is of key significance for augmented reality applications and engine learning ideal models in which the place of CoM or joint point ought to be shown progressively for analyzing or preparing coordinated abilities.

Test plans executed in a step research facility are, for the most part, very much controlled and regularly have a high dependability. Be that as it may, dissimilar to research facility settings with a power stage or camera movement examination framework, wearable sensors permit field concentrates on reflecting genuine live circumstances in the preparation and rivalry climate. The live estimation of equilibrium by estimating CoM during normalized circumstances in group activities, such as free shots in b-ball, becomes conceivable. Also, the pre-owned strategy permits the coach to give constant visual input to the competitors concerning their COM influence. Past exploration has shown that this technique has further developed walk dependability.

Conclusion

In summary, this study proposed a basic framework given two wearable sensor modules connected to subjects lower back and a rearranged biomechanical human body model for assessing the focal point of mass direction with high consent to the optical reference framework (r>0.9) (Mo et al., 2019). The proposed framework defeats the inadequacies of research facility-based estimating frameworks by involving moderately reasonable scaled-down MEMS innovation for balance appraisal in free condition autonomous of surface kind or testing climate. Furthermore, this finding might boost the surveys on postural control in patients and competitors by proposing novel standards that were unachieved before. This is important since the aim of this study was to investigate the precision of wearable sensors to assess the center of mass (COM) direction during huge body fragment developments.

This study shows that wearable innovation given inertial sensors is precise in gauging mass direction focus in complex athletic errands (Rajkumar et al., 2019). The paper suggests that the two-interface model of human body gives ideal trade-off among precision and least number of sensor module for assessment of focus of mass direction, specifically during quick developments. Wearable innovations given inertial sensors are practical choice for evaluating dynamic postural control in complex undertakings outside of walk research facilities and imperatives of cameras, surface, and base of help.

Lastly, the paper shows that inconsistencies can also represent the exploratory convention, the marker arrangement, and skin development. Regardless of these restrictions, the assessed exactness was somewhat high and had all the earmarks of being enough for assessment of COM direction. This study also explored the accuracy of different simplified models for estimating the trajectory of COM. We established that by means of estimation of lower back movement does not exactly signify COM motion especially during fast movements.

Reference List

Carpentier, J., Benallegue, M. and Laumond, J.P. (2017) ‘On the centre of mass motion in human walking’, International Journal of Automation and Computing, 14(5), pp.542-551.

Ghislieri, M., Gastaldi, L., Pastorelli, S., Tadano, S. and Agostini, V. (2019) ‘Wearable inertial sensors to assess standing balance: A systematic review’, Sensors, 19(19), p.4075.

Houchen-Wolloff, L., Williams, J.E., Green, R.H., Woltmann, G., Steiner, M.C., Sewell, L., Morgan, M.D. and Singh, S.J. (2018) ‘Survival following pulmonary rehabilitation in patients with COPD: the effect of program completion and change in incremental shuttle walking test distance’, International journal of chronic obstructive pulmonary disease, 13, p.37.

Howell, D.R., Hanson, E., Sugimoto, D., Stracciolini, A. and Meehan III, W.P. (2017) ‘Assessment of the postural stability of female and male athletes’, Clinical journal of sport medicine, 27(5), pp.444-449.

Hsu, Y.L., Yang, S.C., Chang, H.C. and Lai, H.C.( 2018) ‘Human daily and sport activity recognition using a wearable inertial sensor network’, IEEE Access, 6, pp.31715-31728.

Huntley, A.H., Schinkel-Ivy, A., Aqui, A. and Mansfield, A.( 2017) ‘Validation of simplified centre of mass models during gait in individuals with chronic stroke’, Clinical Biomechanics, 48, pp.97-102.

Kumar, S.L., Aravind, H.B. and Hossiney, N. (2019) ‘Digital image correlation (DIC) for measuring strain in brick masonry specimen using Ncorr open source 2D MATLAB program’, Results in Engineering, 4, p.100061.

Lau, G.K. and Shrestha, M. (2017) ‘Ink-jet printing of micro-electro-mechanical systems (MEMS)’, Micromachines, 8(6), p.194.

Mo, F., Li, J., Dan, M., Liu, T. and Behr, M. (2019) ‘Implementation of controlling strategy in a biomechanical lower limb model with active muscles for coupling multibody dynamics and finite element analysis’, Journal of biomechanics, 91, pp.51-60.

Nachamai, M., Paulose, J. and Marandi, S. (2018) ‘A comparative analysis of the efficiency of video reader object for frame extraction in MATLAB’, J. Multim. Process. Technol., 9(1), pp.16-21.

Noacco, V., Sarrazin, F., Pianosi, F. and Wagener, T. (2019) ‘Matlab/R workflows to assess critical choices in Global Sensitivity Analysis using the SAFE toolbox’, MethodsX, 6, pp.2258-2280.

Rajkumar, A., Vulpi, F., Bethi, S.R., Wazir, H.K., Raghavan, P. and Kapila, V. (2019) ‘Wearable inertial sensors for range of motion assessment’, IEEE sensors journal, 20(7), pp.3777-3787.

Ravindra, V.M., Senglaub, S.S., Rattani, A., Dewan, M.C., Härtl, R., Bisson, E., Park, K.B. and Shrime, M.G. (2018) ‘Degenerative lumbar spine disease: Estimating global incidence and worldwide volume’, Global spine journal, 8(8), pp.784-794.

Wan, S., Zhu, Z., Yin, K., Su, S., Bi, H., Xu, T., Zhang, H., Shi, Z., He, L. and Sun, L. (2018) ‘A highly skin‐conformal and biodegradable graphene‐based strain sensor’, Small Methods, 2(10), p.1700374.

Wilkinson, R.D. and Lichtwark, G.A. (2021) ‘Evaluation of an inertial measurement unit-based approach for determining centre-of-mass movement during non-seated cycling’, Journal of Biomechanics, 126, p.110441.

Print
More related papers
Cite This paper
You're welcome to use this sample in your assignment. Be sure to cite it correctly

Reference

IvyPanda. (2024, March 3). Wearable Inertial Sensors for Centre of Mass Stability Changes. https://ivypanda.com/essays/wearable-inertial-sensors-for-centre-of-mass-stability-changes/

Work Cited

"Wearable Inertial Sensors for Centre of Mass Stability Changes." IvyPanda, 3 Mar. 2024, ivypanda.com/essays/wearable-inertial-sensors-for-centre-of-mass-stability-changes/.

References

IvyPanda. (2024) 'Wearable Inertial Sensors for Centre of Mass Stability Changes'. 3 March.

References

IvyPanda. 2024. "Wearable Inertial Sensors for Centre of Mass Stability Changes." March 3, 2024. https://ivypanda.com/essays/wearable-inertial-sensors-for-centre-of-mass-stability-changes/.

1. IvyPanda. "Wearable Inertial Sensors for Centre of Mass Stability Changes." March 3, 2024. https://ivypanda.com/essays/wearable-inertial-sensors-for-centre-of-mass-stability-changes/.


Bibliography


IvyPanda. "Wearable Inertial Sensors for Centre of Mass Stability Changes." March 3, 2024. https://ivypanda.com/essays/wearable-inertial-sensors-for-centre-of-mass-stability-changes/.

Powered by CiteTotal, easy citation website
If, for any reason, you believe that this content should not be published on our website, please request its removal.
Updated:
Cite
Print
1 / 1